Actuator Styles and Their Operation |
| |
| Explanation of Parameters |
| Symbol |
Parameter |
Unit |
Explanation |
| D |
Datum |
- |
Reference line to establish actuator's
FP |
| FP |
Free Position |
mm or angle |
Normal actuator position with no
force applied. Shown as angle from D |
| OP |
Operating Position |
mm or angle |
Actuator's operating position; causes
change of output |
| TTP |
Total Travel Position |
mm or angle |
Position at actuator's maximum travel |
| PT |
Pretravel |
mm or angle |
Travel angle or travel distance
between FP and OP |
| OT |
Overtravel |
mm or angle |
Travel angle or travel distance
between OP and TTP |
| OF |
Operating Force |
g |
Operating force to move actuator
from FP to OP |
|
 |
|
| |
| Actuator Type and Performance by
Style (Example of OS-5202) |
| |
Dimensions
in mm (1 mm = 0.0394 inches) |
| |
|
| Actuator Type
: A |
Actuator Type
: B |
|
|
|
| |
|
| Actuator Type
: C |
Actuator Type
: D |
|
|
|
| |
|
| Actuator Type
: E |
Actuator Type
: F |
|
|
|
| |
|
| Actuator Type
: G |
Actuator Type
: H |
|
|
|
| |
|
| Actuator Type
: I |
Actuator Type
: J |
|
|
 |
 |
| FP |
+5.5° |
| PT |
18° |
| OF |
1±0.5g |
|
|
| |
|
| Actuator Type
: K |
Actuator Type
: L |
 |
 |
| FP |
-37.5° |
| PT |
18° |
| OF |
1±0.5g |
|
|
|
| |
|
| Actuator Type
: M |
Actuator Type
: N |
 |
 |
| FP |
-14.5° |
| PT |
18° |
| OF |
1±0.5g |
|
|
|
| |
|
NOTE:
FP: Travel to the left from D-->(-), Travel to the right from
D-->(+)
PT: Angle tolerance is ±5° (Photo transistor output),
Angle tolerance is ±3° (Photo IC output) |